Home > Products > Mechanical Type Water Meter > Rotary Type Water Meter > Dry Type Multi Jet Mechanical Brass Water Meter Class B
Dry Type Multi Jet Mechanical Brass Water Meter Class B
Dry Type Multi Jet Mechanical Brass Water Meter Class B
Dry Type Multi Jet Mechanical Brass Water Meter Class B
Dry Type Multi Jet Mechanical Brass Water Meter Class B
Dry Type Multi Jet Mechanical Brass Water Meter Class B
Dry Type Multi Jet Mechanical Brass Water Meter Class B

Dry Type Multi Jet Mechanical Brass Water Meter Class B

External adjustment dry type water meter (LXSG-15-50) is composed mainly of the body, cover, counting mechanism, measuring mechanism, and other components, the counting mechanism and the impeller are completely isolated by the magnetic drive , and the word wheel reading part is dry and separated from the use of water for a long time to maintain a clear part of the reading, with antifreeze, anti-fog, Anti-fouling, and other features .

Application:

Measuring the qtotal volume of cold (hot ) water passing through the pipeline.

Main features:

1) Simple structure.
2) Easy to manufacture and maintain, low cost.
3) Durable, low water quality requirements.
4) Error is easy to adjust.
5) Flow ratio is relatively large.
6) Sensitivity is better.
7) Straight pipe requirements are lower.

Working Conditions:

Temperature classes: T30 T50 T90
Water pressure classes: MAP16 MAP10
Pressure-loss classes: △p63

Accuracy:

From minimum flow rate (Q1) inclusive to transitional flow rate (Q2) exclusive:±5%
From transitional flow rate (Q2) to overload flow rate (Q4): ±2% (Hot water meter:±3%)

Outline diagram:

Dimensions and weight:

DN

Length (mm)

Width (mm)

Height (mm)

Connecting thread

Weight

(Kg)

L

L1

B

H

d

D

15

259

165

96

106

R1/2

G3/4 B

1.26

20

294

190

96

107

R3/4

G1 B

1.5

25

382

225

101

114

R1

G1 1/4 B

2.48

32

385

230

101

114

R1 1/4

G1 1/2 B

2.81

40

430

300

4.89

50

446

300

5.94

Main technical parameters and measuring range:

DN

Q4

Q3

Q2

Q2/Q1=1.6 m3/h

Q1

R (Q3/Q1) m3/h

Min. reading

Max. reading

m3/h

R80

R100

R125

R160

R80

R100

R125

R160

m3

m3

15

3.125

2.5

0.05

0.04

0.032

0.025

0.032

0.025

0.02

0.016

0.00005

99999

20

5

4

0.08

0.064

0.05

0.04

0.05

0.04

0.032

0.025

0.00005

99999

25

7.875

6.3

0.126

0.1

0.08

0.063

0.08

0.063

0.5

0.4

0.00005

99999

32

12.5

10

0.2

0.16

0.125

0.1

0.125

0.1

0.08

0.063

0.00005

99999

40

20

16

0.32

0.256

0.2048

0.16

0.2

0.16

0.128

0.1

0.00005

99999

50

31.25

25

0.5

0.4

0.32

0.25

0.3125

0.25

0.2

0.156

0.00005

99999

Error curve: